Jakarta, INTI - The growing demand for artificial intelligence (AI)-based computing is pushing data center operators in Indonesia to expand capacity while improving infrastructure efficiency.
One of the key challenges is ensuring that increasing computing workloads are supported by more efficient cooling systems to keep energy consumption under control. Power requirements for AI-based data centers can now reach 100 to 200 kilowatts (kW) per server rack, significantly higher than conventional facilities, which are generally designed to handle power densities ranging from the low teens to several dozen kilowatts per rack.
This shift presents a particular challenge for Indonesia’s data center industry, as facilities across the country operate in tropical climates characterized by high temperatures and humidity throughout the year.
Data Center Sales Manager at Midea Building Technology (MBT), Andi Terahady, explained that tropical conditions create different operational challenges for Indonesian data center operators compared with those in countries with four distinct seasons. In colder regions, operators can utilize low-temperature outdoor air through free cooling for several months to reduce the electricity consumption of cooling equipment.
“By contrast, facilities in Indonesia must work harder to overcome high ambient temperatures almost every day, while regulations and global customers increasingly demand competitive Power Usage Effectiveness (PUE) ratios below 1.5, and even approaching 1.2,” Andi said in a statement received on Sunday, November 22, 2026.
According to Andi, increasing power density in AI server racks is also pushing conventional air-cooling approaches toward their physical limitations.
At the same time, operators must manage hotspots in high-density racks without compromising operational reliability around the clock, seven days a week.
To address these requirements, Midea Building Technology has introduced an integrated cooling architecture combining high-efficiency magnetic bearing chillers, fan walls, and liquid cooling solutions based on Coolant Distribution Units (CDUs).
“The increase in AI server rack density to 100–200 kW requires a fundamental shift in how we manage heat. Through closed-loop liquid cooling systems and active CDUs that integrate chiller and liquid distribution functions into a compact unit, heat removal becomes significantly more precise while reducing unnecessary water and space consumption,” he explained.
Andi added that closed-loop liquid cooling technology is also important for maintaining water efficiency, as measured by Water Usage Effectiveness (WUE).
With this approach, data center operators must not only pursue lower Power Usage Effectiveness (PUE) ratios but also maintain a balance in their carbon footprint through Carbon Usage Effectiveness (CUE).
Sustainability Standards Become Increasingly Important for Data Centers
Beyond cooling technology requirements, environmental sustainability is also becoming a major consideration in data center industry development.
Executive Director of the Indonesia Data Center Provider Organization (IDPRO), Michael Abimanyu, emphasized that data center facilities should generate added value for the digital economy without placing excessive pressure on the surrounding environment. This is particularly important in relation to raw water availability and clean electricity supplies.
To support these objectives, IDPRO has developed Indonesian National Standards (SNI) 8799 Books 1 through 3, drawing on the Green Data Center study presented in its 2023 white paper.
“We are currently formulating SNI 8799 Book 4 in collaboration with the Ministry of Communication and Digital Affairs (Komdigi) and the National Standardization Agency (BSN),” Michael explained.
In addition to developing national standards, IDPRO is preparing a self-assessment instrument called the Sustainable Data Center Index to encourage the adoption of sustainability principles in data center operations.
The instrument classifies data center facilities into three rating levels: light green, green, and dark green, with scores weighted according to several sustainability criteria.
Carbon emissions management carries the highest weighting at 50%. The operational parameters include renewable energy utilization, reductions in operational emissions, and Carbon Usage Effectiveness (CUE) monitoring.
Energy efficiency accounts for 30% of the assessment. This category focuses on optimizing electrical and cooling systems to reduce Power Usage Effectiveness (PUE).
Meanwhile, environmental and water management account for the remaining 20%. The evaluation covers water conservation through Water Usage Effectiveness (WUE), the adoption of closed-loop technologies, and the alignment of data center facilities with the water resources available at their respective locations.
Conclusion
The growing demand for AI computing is transforming Indonesia’s data center industry, requiring operators to expand capacity while improving cooling efficiency and operational reliability. Advanced solutions such as liquid cooling, combined with stronger sustainability standards, will play an increasingly important role in managing energy consumption, water usage, and carbon emissions. As Indonesia continues to develop its digital infrastructure, balancing technological growth with environmental responsibility will be essential to building a sustainable and competitive data center ecosystem.